FanTestic

  1. Why does FanTestic start at the highest pressure first?

    We start at the highest pressure and work downward for two reasons. 

    1. It helps the fans reach the target pressures faster. The speed control algorithm works faster going from a higher pressure to a lower pressure.
    2. It helps you properly select your Range Ring for the test. By starting with the largest possible range (highest flow) to test at your highest pressure you ensure the minimum possible range changes while testing. Ideally, you don't want to change ranges in mid test because it wastes time. 
    Read more »
  2. Why does my Q4 (flow at 4 Pa) result have such high uncertainty?

    You need to consider that there is a fundamental issue of uncertainty with using 4 Pa as a reference pressure. Just imagine, if there is even a 1 Pa fluctuation, due to so many possible sources that can cause pressure fluctuations as you know, the pressure measurement already has an uncertainty of +/- 25% error. Consider that for almost all airtightness testing standards across the world, the reference pressure for Flow results are either 50 Pa or 75 Pa.

    Read more »
  3. How do I get the latest version of FanTestic?

    Updates of FanTestic are released regularly.  How do I know if I have the latest version, and how do I get it?

    Users who are using the ADMIN shortcut with FanTestic or who have skipped an update will not necessarily be notified of the update when they start the software. 

    To install the new FanTestic:

    If you have a current version of  FanTestic, open it while connected to the internet, use the File menu>>Check for Updates  and then restart if it tells you that there is a new version available. (old versions of FanTestic do not have this option in the File menu, and some old versions have it but it can crash on some computers).

    If you have trouble installing the update using the "Check for Updates", uninstall FanTestic using the control panel and re-install from the following link:

    Read more »
  4. How do I install FanTestic or Integrity using Chrome, Firefox, or MS Edge browsers?

    If you are using a browser that is NOT Microsoft Internet Explorer you may get errors when you run the setup.exe that you downloaded.  If you get errors, use Microsoft Internet Explorer and choose to "Run" the installer from the internet rather than downloading.

     The FanTestic and Integrity installer relies on the use of the Internet Explorer Browser, as do all applications distributed using ClickOnce technology.  In order to successfully install, start Internet Explorer on your computer and navigate to the download link in Internet Explorer.  If your computer has a different browser set as default, you will have to copy the link from that browser into Internet Explorer.

    On Windows 10, the new Microsoft Edge browser is NOT Internet Explorer.  On Windows 10, you must type "Internet Explorer" into the Cortana search bar and choose to open "Internet Explorer (desktop)".

    If you continue to have errors installing when using Inter

    Read more »
  5. My duct test using DW/143 is not compliant, what am I doing wrong?

    I am doing duct testing and use the DW/143 standard (UK).  FanTestic keeps telling me the test is not compliant, what am I doing wrong?

    FanTestic checks that you have held the ducts at the test pressure for at least 900 seconds.  If you do not, the test will show as not compliant.  If you did a manual test and are entering the information into FanTestic, be sure to enter the time over which the test pressure was held.  If this is greater than 900 and your other test conditions are correct, the test will show compliant. 

    Compliance means the test conditions comply with the stated requirements for a test  in DW/143.  Pass or fail means that the measured results are within the required level.

    Read more »
  6. How do I get the factory default report template for FanTestic?

    FanTestic provides a report template that users with Pro licenses can customise.  If users have done customizations and not given the template a name different than the default template, they will not always be able to see the new factory template after a FanTestic update.

    FanTestic provides a report template that users with Pro licenses can customise.   This template can then be used when the user generates a report from their test data. 

    One  way to get a copy of the current factory default template is to use the menu item in the File menu called "Customize Report Template".  This will create a copy of the factory default template in the MyDocuments\Retrotec\Templates directory with the name of the factory default template plus "_To_Customize-[yyyy-MM-dd]".

    The default Template is named with the name of the standard you are using, and the language.   So if you are using ASTM standard with t

    Read more »
  7. Can I install FanTestic on a Windows 8 computer?

    FanTestic will install properly on a Windows 8 computer, as long as it is full Windows 8 and not one of the tablet or phone versions of Windows 8. 

    Make sure to disable anti-virus while doing the download and install. 

    Be sure to “Run” the installer from the internet using Internet Explorer browser, do not download it to the computer and then run it.

    If you have trouble installing FanTestic, you can first install the DM32 USB Driver directly from the website (the version on the website has an up to date certificate) and then run the FanTestic installer. 

    (Older versions of the FanTestic installer had a DM32 USB Driver which did not have an up to date security certificate so some settings on Windows 8 could cause it to reject the installation. )

    Read more »
  8. FanTestic could not recover the USB connection to my DM32 gauge. How do I fix this?

    1. If using a USB connection, and FanTestic advises you to unplug and re-plug the USB, you must re-plug into a Different USB port.

    2. If you are using USB connection from your computer to the gauge, we recommend that you try the Ethernet connection.  Instructions for directly connecting the blue Ethernet cable from your computer to the gauge are provided on the last page of the DM32 QuickGuide.  Follow the instructions for connecting to a switch using a "Static" connection. https://retrotec.com/pub/media/mageworx/downloads/attachment/file/q/u/quickguide_for_dm32_gauge.pdf 

    Read more »
  9. Test data appears in red font. What does this mean?

    There are two cases when you will see red test data in FanTestic:

    1. Fan Pressure (flow pressure) is too low for the Range, which means you should change to a smaller, more restrictive, Range – During an Automatic test, the software would prompt you to change the Range in this case.
    2. During data collection, there was a data point collected as zero - This is caused by an instantaneous Fan pressure dropout, and the software displays this result in red to indicate data may have been skewed and should be retaken.

    If you did not receive a prompt to change Range, most likely the problem is #2. In this case, you should just click the "Clear point" button to clear that specific data point and you can re-input data back into that specific point using Semi-Automatic mode via the "Begin Semi-Automatic" button.

    Read more »
  10. How do I fix the error: "The signature of this program is corrupt or invalid" when I try to install Retrotec software?

    This problem is often caused by anti-virus programs. In particular we have found that using Internet Explorer and a virus protection program from Microsoft called 'Windows Smartscreen'.

    Disable your anti-virus program, uninstall the earlier version and download and install the new version from the website:

    https://retrotec.com/software.html

    Read more »