Install any number of fans in any opening with our new stacking panel that replaces the old 3 Fan Folding Panel used in the Model QMG.
It also includes the newly released, industry changing DM32X gauge.
Why “stacking”? Carry them to the test site in a stack that is 30x30” and as high as needed for any number of fans. Get a lot more panels in a small space making shipping faster, cheaper and easier.
Just clamp a wood frame into any size of opening and use blank sheets to fill other openings as needed. Then screw the Stacking Panels onto the frame and you can snap in any number of Model 1000, 5000 or 6000 Fans. That’s it- you’re ready to test.
Advantages:
- Faster to install
- One tenth the panel leakage
- Fits any size opening
- Fans won’t fall out
These same panels permit:
- Under Floor Air Distribution (UFAD) testing with Model 1000, 5000 or 6000 Fans
- Rain Penetration Tests with 6000 Fans
- Large Commercial ducts with 4000 Fans
- Durable design
- Easy folding set up
- Light-weight construction
- Includes carrying case
3 x Stacking Panel for 1000/5000/6000 Fans
1 x Stacking Panel Carrying Case
3 x Fan Safety Strap for Modular Panels for 1000/5000/6000 Fans
36 x Stacking Panel Screws
3 x DM32X Gauge Package
- DM32X Gauge (Newly Released! click here for details)
- USB-C Charging Cable
- Cat5 Cable
- Gauge Case
- DM32X Magnetic Clip
- ISO17025 calibration of DM32X
- Gauge Calibration Verification Report
3 x 6000 Series Fan Set
- Each fan set contains:
- 6000 Series Calibrated Fan
- High Power Drive for 6000 Series Fan (120V/60Hz, 240V/50Hz, or 110V/50Hz)
- Range Ring A for 5000/6000 Series Fan
- B8 Plate for 5000/6000 Series Fan
- 8 x 4" Blank Plugs
- 2 x Fan Cover
- System Calibration Verification Report
3 x Case for System Accessories
3 x Fan Case
3 x Blower Door Tubing Kit
3 x Umbilical for 1000/5000/6000 Series Fan, 7 ft (2 m)
|
Model: |
Stacking Panel |
|
Part Number: |
PN314 |
|
Compatible Fan(s): |
1000/5000/6000 |
|
Individual Panel (H x W x D) |
31 5/8th x 31 5/8th |
|
|
|
Model 6000 Fan |
||||
|
|
Flow Into: |
CFM |
Litres/sec |
M3/h |
|
Max Flow, per fan (60 Hz) |
Free Air |
8,100 |
3,823 |
13,762 |
|
50 Pa |
7,700 |
3,634 |
13,082 |
|
|
75 Pa |
7,400 |
3,492 |
12,573 |
|
|
Minimum Flow: |
|
|
|
|
|
on Included Range B1 |
50 Pa |
95 |
49 |
161 |
|
on Optional Range 74 |
50 Pa |
37 |
17 |
63 |
|
on Optional Range 47 |
50 Pa |
21 |
10 |
35 |
|
on Optional Range 29 |
50 Pa |
9 |
4 |
15 |
|
Dimensions: |
22" (55.9 cm) inlet diameter, 9.75" (24.8 cm) long, 25" (63.5 cm) height |
|||
|
Weight: |
33.5 lb (15.2 kg) or 35.2 lb (16.0 kg) with Ring A & Plated B8 installed |
|||
|
Flow Accuracy: |
+/-5% |
|||
|
Power: |
120V@60hz/11A or 240V@50hz/4.9A or 110V@50Hz/ 8.9A |
|||
|
Recommended Fan Calibration Interval: |
5 years |
|||