How It Works
Setup your equipment. Open rCloud on your DM32X, smartphone, or tablet, enter the address and select the type of test – rCloud does the rest.
rCloud allows anyone with a mobile device to perform a fully automated blower door or duct test. The rCloud app provides secure and accurate data that includes the location where the test was performed, local weather, set-up conditions, photos and the calibration date of the gauge. In some markets, rCloud will provide existing housing data.
The rCloud app connects directly to the DM32 WiFi smart gauge to perform your test. The data and images are stored on a remote secure server. The account can have multiple users and the reports can be viewed in the app or online.
Security And Privacy
Data is collected securely, time/date-stamped, geo-tagged, and uploaded to a cloud storage. While the data is stored in the device it is encrypted and cannot be altered. The data is uploaded when an internet connection is available. Data storage is secured through Microsoft Azure.
The data is secure the moment the test is completed.
Quality Assurance
The rCloud app provides quality assurance for the user and entire team. It assures the tests were performed in compliance with the testing standards and the data was collected directly from the gauge. No more pencil and paper or lost test results.
Testing Standards
The rCloud app currently includes testing standards for International Energy Conservation Code 2009, 2012 and 2015, RESNET and California Title 24 standards.
This includes duct testing and single and multipoint blower door tests. We are currently implementing RESNET/ANSI standard 380 and European test standards.
Additional testing standards will be added.
Data Management
One of the most powerful benefits of rCloud is the ability to see all the test locations on a map. Select any location and see all the test performed at that location then select a test to see and share the compliance report.
Future
Retrotec has never stopped providing innovation. We believe that automated secure data is the future of our industry. Join us as we provide the Future of Testing to everyone.
Testing Standards Supported
RESNET
Blower Door Tests:
ICC380 2016 Single Point
ICC380 2016 Multi-point
Chapter 8 Multi-point
Chapter 8 Repeated Single Point
Chapter 8 Single Point
Duct Tests:
ICC380 2016 Single Point Total Leakage Test
Chapter 8 Single Point Total Leakage Test
Exhaust Fan Tests
ICC380 2016 Passive Resistance Test
International Energy Conservation Code IECC
Blower Door Tests:
IECC 2015 Multi-point
IECC 2015 Repeated Single Point
IECC 2012 Single Point
Duct Tests:
IECC 2012 Single Point
California Title 24
Blower Door Tests:
CA Title 24 Multi-point Test
CA Title 24 Single Point
IECC 2012 Single Point
Duct Tests:
CA Title 24 Single Point
Weatherization
IECC 2012 Single Point Blower Door
ATTMA (UK)
Blower Door Tests:
Single Direction Multi-point Test
Dual Direction Multi-point Test
ISO9972 (Europe)
Blower Door Tests:
Single Direction Multi-point Test
Dual Direction Multi-point Test
ISO9972 (France)
Blower Door Tests:
Single Direction Multi-point Test
Dual Direction Multi-point Test
FAQs
Yes, you can print your results via the rCloud portal. Just log in to the rCloud web portal, find your report, and you can save your report as a PDF to be printed.
Outside of the DM32X where rCloud is already pre-loaded and installed, rCloud works with a WiFi enabled DM32 gauge only.
Yes, you can access your compliance report via the rCloud web portal. Just login to the rCloud web portal, find your report and you can save and share your report as a PDF.
Yes, you can print your results via the rCloud web portal. Just login to the rCloud web portal, find your report and you can save your report as a PDF to be printed.
rCloud only works with Retrotec WiFi enabled DM32 gauge.
The DM32 smart gauge can run the Energy Conservatory Duct BlasterTM and blower door fans. Requires the Retrotec Speed Control Adapter