7120 Hard Panel Blower Door System
Singapore
Local Resellers
Energy Conservation Technologies Pty Ltd
Contact Reseller
Model 7120 Hard Panel System
Experience the next level of professionalism with the Retrotec 7120 System. This hard panel system, adapted with the advanced 7000 Series fan, offers an incredibly rapid setup and a sleek, professional appearance that makes it a favorite among top building science companies.
Revolutionary Design and Power
The 7120 System incorporates the revolutionary blower door fan from the 7000 Series, which is over 30% lighter than previous models. Weighing just 23 lbs (10.4 kg), compared to its 33.5 lbs (15 kg) predecessors, it delivers unmatched portability and ease of use.
Unmatched Performance
The 7120 System is designed to deliver higher CFM @ 50Pa than the Model 5000 Fan and often more than the 6000 fan, ensuring it meets the rigorous demands of residential and small commercial testing.
Professional and Efficient Setup
The hard panel system offers a clean, professional look, ideal for multi-story buildings where one or two high-power fans per floor are typically sufficient. This design not only enhances the visual appeal but also ensures a quick and efficient setup, saving valuable time on the job site.
Advanced Features with the DM32X Gauge:
- Real-Time Graphing & Data Logging: Effortlessly capture and analyze data.
- Built-In Testing and Training Apps: Streamline your testing processes with integrated applications.
- Comprehensive Support: Access embedded and online manuals, videos, and resources for seamless operation.
1 x 7000 Series Fan Set
- 7000 Series Calibrated Fan
- High Power Drive for 7000 Series Fan (120V/60Hz, 240V/50Hz, or 110V/50Hz)
- Range Ring A for 7000 Series Fan
- B8 Plate for 7000 Series Fan
- 8 x 4″ Blank Plugs
- 2 x Fan Cover
- System Calibration Verification Report
1 x DM32X Gauge Package
- DM32X Gauge (Newly Released! click here for details)
- USB-C Charging Cable
- Cat5 Cable
- Gauge Case
- DM32X Magnetic Clip
- ISO17025 calibration of DM32X
- Gauge Calibration Verification Report
1 x Hard Panel Set for 1000/5000/6000/7000 Series Fan
1 x Hard Fan Case
1 x Accessory Case
1 x Blower Door Tubing Kit
1 x Umbilical for 7000 Series Fan
| Model 7000 Fan | ||||
| Flow Into: | Flow – Battery | Flow 120/240V (CFM / M3H) | ||
| Max Flow, per fan | Free Air | 8,900 CFM • 15,121 m3/h • 4,2001/s | 7,850 CFM / 9,342 CFM • 15,872 m3/h | |
| 50 Pa | 8,413 CFM • 14,302 m3/h • 3,970 1/s | 7,358 CFM / 8,896 CFM • 15,115 m3/h | ||
| 75 Pa | 8,136 CFM • 13,823 m3/h • 3,840 1/s | 7,054 CFM / 8,637 CFM • 14,675 m3/h | ||
| Minimum Flow: | ||||
| on Included Range B1 | 60 Pa | 120 CFM • 204 m3/h • 57 1/s | ||
| on Optional Range 74 | 50 Pa | 51 CFM • 86 m3/h • 24 1/s | ||
| on Optional Range 47 | 50 Pa | 24 CFM • 40 m3/h • 11 1/s | ||
| on Optional Range 29 | 50 Pa | 8 CFM • 14 m3/h • 4 1/s | ||
| Dimensions: | 22″ (55.9 cm) inlet diameter, 9.75″ (24.8 cm) long, 25″ (63.5 cm) height | |||
| Weight: | Fan Only : 23 lbs/ 10.43 kg Fan + Ranges: 25.4 lbs/ 11.52 kg Power Supply: 13.4 lbs/ 6.08 kg Battery Pack: 15.6 lbs/ 7.07 kg |
|||
| Battery Pack Runtime: | 24 minutes at 100% continuous use 88 minutes at 50% continuous use Full charge in 4.5 hrs |
|||
| Flow Accuracy: | +/-5% | |||
| Digital Gauge Model: | DM32X (Click Here) | |||
- Manual Blower Door Operation 300 5000 6000 70003.6 MB
- Manual DM32X Operation3.8 MB
- Manual FanTestic ASTM2.5 MB
- Manual FanTestic ATTMA2.8 MB
- Manual FanTestic CGSB2.5 MB
- Manual FanTestic Duct Testing2.7 MB
- Manual FanTestic EN 13829 ISO 9972 2015 Europe3.4 MB
- Manual FanTestic EN13829 Belgium2.7 MB
- Manual FanTestic EN13829 Denmark2.6 MB
- Manual FanTestic EN13829 Europe2.7 MB
- Manual FanTestic EN13829 France2.7 MB
- Manual FanTestic EN13829 Italy2.2 MB
- Manual FanTestic EN13829 Sweden2.7 MB
- Manual FanTestic Guide Utilisation EN13829 French1.5 MB
- Manual FanTestic How To Customize Generated Reports1.7 MB
- Manual FanTestic ISO 99722.7 MB
- Manual FanTestic USACE2.6 MB
- QuickGuide Door Panel Cloth Folded Version3.6 MB
- QuickGuide DM32X Operation4.6 MB
- QuickGuide Blower Door With DM32X For Model 300 5000 6000 70008.7 MB
- QuickGuide DoorPanel Modular QG2101.1 MB
- Sample ISO Accredited Gauge Calibration Certificate140.2 KB