DM32
The DM32 is no longer for sale and has been replaced by the DM32X. To view the DM32X, CLICK HERE
Retrotec continues to provide calibration and repair services for the DM32. For calibration or repair, CLICK HERE
Out of stock
The DM32 is no longer for sale and has been replaced by the DM32X. To view the DM32X, CLICK HERE.
Retrotec continues to provide calibration and repair services for the DM32.
1 x DM32 Gauge Package
- DM32 Gauge
- DM32 Charger + Power Supply
- DM32 Gauge Case
- ISO 17025 Accredited Gauge Calibration & Certificate
|
Gauge Model: |
DM32W | ||
| Dimensions: | 5.8″ × 3.6″ × 1.4″ (14.7 × 9.2 × 3.5 cm) | ||
| Weight: | 12 oz (340 g) | ||
| Power: | 4200 mAh LiPoly rechargeable battery. Integrated on board charging circuit.
Up to 11 hours battery life on a single charge. (Battery life and charge cycles vary by use and settings; actual results will vary.) |
||
| Screen type: | QVGA Color touchscreen LCD display | ||
| Screen dimensions: | 3.2” (8.2 cm) diagonal, 2.6″ × 1.9″ (6.6 × 5.0 cm) | ||
| Microcontroller: | 32 bit | ||
| Pressure channels: | 2 independent pressure channels (“A” & “B”) | ||
| Pressure sensor type: | Digital | ||
| Pressure range: |
DM32-10A (current version)
DM32-4A (no longer sold)
DM32-20A (current version for commercial ductesters)
* DM32-20A started shipping Jan 2015 * DM32-10A started shipping Oct 2017
|
||
| Pressure resolution: | 0.1 Pa (0.004 in WC, 0.002 psf) | ||
| Pressure accuracy: | DM32-10A (current version) +/- 0.4% of pressure reading or +/- .07 Pa @ 22 degree (C)+/- 0.6% of pressure reading or +/- .15 Pa @ 0 – 44 degree (C)+/- 0.9% of pressure reading or +/- 1 Pa @ 70 degree (C)DM32-4A (no longer sold) ±1% of pressure reading or ±0.25 Pa (whichever is greater)DM32-20A (current version for commercial ductesters) ±1% of pressure reading or ±1.0 Pa (whichever is greater) |
||
| Pressure accuracy calibration meets: | USACE, ASTM E779, CGSB-149.10, EN 13829, UK ATTMA TSL1 and TSL2, NFPA 2001, ISO 14520, EN15004, ISO9972
the DM32-20A does not meet these standards and is meant to be used for high pressure testing where 1 Pa or 1% is adequate accuracy |
||
| Temperature Ranges: | Compensated: 32°F to 158°F (0°C to 70°C)Operating Storage: -13°F to 185°F (-25°C to 85°C) -40°F to 257°F (-40°C to 125°C) |
||
| Humidity Limits (non condensing) |
0 to 95% RH | ||
| PC Connectivity options (MS Windows only): | Ethernet (direct or over network), USB (direct), Wireless via WiFi | ||
| WiFi 802.11 protocols: | b/g/n | ||
| Recommended calibration interval: | Every 5 years |