The Most Popular Blower Door System for Residential & Small Commercial Applications
Retrotec’s 5100 Blower Door System is our best-selling solution, outselling all other makes and models on the market. Perfect for testing any residential home, this system comes complete with everything you need: the advanced DM32X gauge, a powerful fan, six ranges, connectors, software, and a durable fan shell backed by an industry-leading 10-year warranty.
Designed for both fully automatic and manual operation, the 5100 features a quick-connect frame with an extra crossbar for added stability and convenient gauge mounting. The system includes Retrotec’s SmartCloth,™ with built-in bias pressure tubing to act as a wind dampening tool.
With everything included, it’s an all-in-one solution that delivers unmatched performance and reliability.
Who Uses the 5100?
This versatile system is trusted by energy auditors, building contractors, HVAC contractors, remodelers, and home inspectors. Whether you’re conducting energy audits, ensuring HVAC efficiency, or inspecting building envelopes, the 5100 is built to meet your needs.
1 x 5000 Series Fan Set
- 5000 Series Calibrated Fan
(120V/60Hz, 240V/50Hz, or 110V/50Hz) - Range Ring A
- B8 Plate
- 8 x Blank Range Plugs
- Blower Door Tubing Kit
- Tubing Umbilical
- Fan Cover
- Power Cord
- System Calibration Verification Report
1 x SmartCloth™ Door Panel & Frame
- SmartCloth™ Wind Dampening Cloth Door
- Aluminum Frame, Etched with Sizing Markings
- Traveling Case
1 x DM32X Gauge Package
- DM32X Gauge
- Gauge Case
- USB-C Charging Cable
- Cat5 Cable
- ISO17025 calibration of DM32X
- Gauge Calibration Verification Report
| Model 5000 Fan | ||||
| Flow Into: | CFM | Litres/sec | M3/h | |
| Max Flow, per fan (60 Hz)
Reduces values by 15% for 50Hz fan |
Free Air | 6,400 | 3,020 | 10,874 |
| 50 Pa | 5,700 | 2,690 | 9,684 | |
| 75 Pa | 5,400 | 2,549 | 9,175 | |
| Minimum Flow: | ||||
| on Included Range B1 | 50 Pa | 111 | 52 | 188 |
| on Optional Range 74 | 50 Pa | 37 | 17 | 63 |
| on Optional Range 47 | 50 Pa | 21 | 10 | 35 |
| on Optional Range 29 | 50 Pa | 9 | 4 | 15 |
| Dimensions: | 22″ (55.9 cm) inlet diameter, 9.75″ (24.8 cm) long, 25″ (63.5 cm) height | |||
| Weight: | 33.5 lb (15.2 kg) or 35.2 lb (16.0 kg) with Ring A & Plated B8 installed | |||
| Flow Accuracy: | +/-5% | |||
| Power: | 120V@60hz/11A or 240V@50hz/4.9A or 110V@50Hz/ 8.9A | |||
| Recommended Fan Calibration Interval: | 5 years | |||
| Digital Gauge Model: | DM32X (Click Here) | |||
- Manual Blower Door Operation 300 5000 6000 70003.6 MB
- Manual DM32 Configurator Software786.5 KB
- Manual DM32 Data Logger1.6 MB
- Manual Dm32 Operation 1 16.7 MB
- Manual DM32 Virtual Gauge1.5 MB
- Manual DM32X Operation3.8 MB
- Manual FanTestic ASTM2.5 MB
- Manual FanTestic ATTMA2.8 MB
- Manual FanTestic CGSB2.5 MB
- Manual FanTestic EN 13829 ISO 9972 2015 Europe3.4 MB
- Manual FanTestic EN13829 Belgium2.7 MB
- Manual FanTestic EN13829 Denmark2.6 MB
- Manual FanTestic EN13829 Europe2.7 MB
- Manual FanTestic EN13829 France2.7 MB
- Manual FanTestic EN13829 Italy2.2 MB
- Manual FanTestic EN13829 Sweden2.7 MB
- Manual FanTestic Guide Utilisation EN13829 French1.5 MB
- Manual FanTestic How To Customize Generated Reports1.7 MB
- Manual FanTestic ISO 99722.7 MB
- Manual FanTestic USACE2.6 MB
- Manual Residential Pressure Air Leakage Testing4.2 MB
- Replacement Items For Model 5000 6000 Blower Doors172.3 KB
- QuickGuide Blower Door With DM32 For Model 5000 60002.5 MB
- QuickGuide Blower Door With DM32X For Model 300 5000 6000 70008.7 MB
- QuickGuide DM32 Operation804.4 KB
- QuickGuide DM32X Operation4.6 MB
- QuickGuide Door Panel Cloth Folded Version3.6 MB
- QuickGuide DoorPanel Modular QG2101.1 MB