Model 6120 Hard Panel System
Incredibly rapid set up and professional appearance of this Retrotec exclusive hard panel system make it very popular among all the top building science companies. Multi-story buildings typically require only one or two high power fans per floor.
It also includes the newly released, industry changing DM32X gauge.
Who uses it?
- Energy Auditors, HVAC Contractors, Building Contractors & Remodelers, Home Inspectors
1 x DM32X Gauge Package
- DM32X Gauge (Newly Released! click here for details)
- USB-C Charging Cable
- Cat5 Cable
- Gauge Case
- DM32X Magnetic Clip
- ISO17025 calibration of DM32X
- Gauge Calibration Verification Report
1 x 6000 Series Fan Set
- 6000 Series Calibrated Fan (120V/60Hz, 240V/50Hz, or 110V/50Hz)
- Range Ring A for 5000/6000 Series Fan
- B8 Plate for 5000/6000 Series Fan
- 1 x High Power Drive for 6000 Series Fan (120V/60Hz, 240V/50Hz, or 110V/50Hz)
- 8 x 4" Blank Plugs
- 1 x Fan Cover
- System Calibration Verification Report
1 x Hard Panel Set for 1000/5000/6000 Series Fan
1 x Hard Fan Case
1 x Accessory Case
1 x Blower Door Tubing Kit
1 x Umbilical for 1000/5000/6000 Series Fan, 7 ft (2 m)
|
Model 6000 Fan |
||||
|
|
Flow Into: |
CFM |
Litres/sec |
M3/h |
|
Max Flow, per fan (60 Hz) |
Free Air |
8,100 |
3,823 |
13,762 |
|
50 Pa |
7,700 |
3,634 |
13,082 |
|
|
75 Pa |
7,400 |
3,492 |
12,573 |
|
|
Minimum Flow: |
|
|
|
|
|
on Included Range B1 |
50 Pa |
95 |
49 |
161 |
|
on Optional Range 74 |
50 Pa |
37 |
17 |
63 |
|
on Optional Range 47 |
50 Pa |
21 |
10 |
35 |
|
on Optional Range 29 |
50 Pa |
9 |
4 |
15 |
|
Dimensions: |
22" (55.9 cm) inlet diameter, 9.75" (24.8 cm) long, 25" (63.5 cm) height |
|||
|
Weight: |
33.5 lb (15.2 kg) or 35.2 lb (16.0 kg) with Ring A & Plated B8 installed |
|||
|
Flow Accuracy: |
+/-5% |
|||
|
Power: |
120V@60hz/22.0A or 240V@50hz/10.9A or 110V@50Hz/22.0A |
|||
|
Recommended Fan Calibration Interval: |
5 years |
|||
|
Digital Gauge Model: |
DM32X |
|
Gauge Specs: |
|
Door Panel and Frame Model: |
PN201 |
|
Type of Panel: |
Hard Panel - Single 1000/3000/5000/6000 Fan |
* The max flow of the fan will vary depending on the following factors: Voltage, frequency, barometric pressure, back pressure, blade pitch, air temperature, bearing tightness, inlet air turbulence
* 5000/6000 series blower doors DO NOT work with the DM-2 digital gauge