Most Professional Looking System
for Residential & Small Commercial
Adding Retrotec’s exclusive modular door panel to the 5000 series fan makes this model the first choice for serious home performance contractors who want to make a positive professional impression. This most professional looking system is quickest to set up with no cloth flapping around. Install and re-pack up in seconds.
Who uses it?
- Energy Auditors, HVAC Contractors, Building Contractors & Remodelers, Home Inspectors
1 x DM32 WiFi Digital Gauge Package
- DM32 WiFi Dual Channel Color Touchscreen Manometer
- USB Cable, 6' (1.8 m)
- Cat5 Cable, 7' (2 m) Blue
- DM32 USB Charging Module (120V/60Hz, 240V/50Hz, or 110V/50Hz)
- Gauge Case
- DM32 Magnetic Clip
- ISO17025 calibration of DM32
- Gauge Calibration Verification Report
1 x 5000 Series Fan Set
- 5000 Series Calibrated Fan (120V/60Hz, 240V/50Hz, or 110V/50Hz)
- Range Ring A for 5000/6000 Series Fan
- B8 Plate for 5000/6000 Series Fan
- 8 x 4" Blank Plugs
- Power Cord
- 1 x Fan Cover
- System Calibration Verification Report
1 x Hard Panel Set for 1000/5000/6000 Series Fan
1 x Blower Door Tubing Kit
1 x Umbilical for 1000/5000/6000 Series Fan, 7 ft (2 m)
- System accessory case
Model 5000 Fan |
||||
|
Flow Into: |
CFM |
Litres/sec |
M3/h |
Max Flow, per fan (60 Hz) |
Free Air |
6,400 |
3,020 |
10,874 |
50 Pa |
5,700 |
2,690 |
9,684 |
|
75 Pa |
5,400 |
2,549 |
9,175 |
|
Minimum Flow: |
|
|
|
|
on Included Range B1 |
50 Pa |
111 |
52 |
188 |
on Optional Range 74 |
50 Pa |
37 |
17 |
63 |
on Optional Range 47 |
50 Pa |
21 |
10 |
35 |
on Optional Range 29 |
50 Pa |
9 |
4 |
15 |
Dimensions: |
22" (55.9 cm) inlet diameter, 9.75" (24.8 cm) long, 25" (63.5 cm) height |
|||
Weight: |
33.5 lb (15.2 kg) or 35.2 lb (16.0 kg) with Ring A & Plated B8 installed |
|||
Flow Accuracy: |
+/-5% |
|||
Power: |
120V@60hz/11A or 240V@50hz/4.9A or 110V@50Hz/ 8.9A |
|||
Recommended Fan Calibration Interval: |
5 years |
Digital Gauge Model: |
DM32 WiFi |
Gauge Specs: |
Door Panel and Frame Model: |
PN201 |
Type of Panel: |
Hard Panel - Single 1000/3000/5000/6000 Fan |
* The max flow of the fan will vary depending on the following factors: Voltage, frequency, barometric pressure, back pressure, blade pitch, air temperature, bearing tightness, inlet air turbulence
* 5000/6000 series blower doors DO NOT work with the DM-2 digital gauge