5100 & 340x COMBO

Our most popular systems for residential blower door & duct testing, combined in one large package.

Includes the newly released DM32X Gauge (x2)

 

$7,950.00

$7,950.00

In stock

SKU
5100 & 340x COMBO

* Required Fields

 

 

Take advantage of discounted pricing when purchasing as a combo. 

Model 5100 Blower Door

Our Most Popular Blower Door System
for Residential & Small Commercial 

Outsells all other makes & models!

Test any residential house. Complete with the newly released DM32X gauge, a fan, 6 ranges, connectors, software and a 10-year warranty on the fan shell. Fully automatic and manual operation. Quick connect frame with extra crossbar for stability and gauge mounting. Everything included.

 

Model 300x DucTester

Maneuver this incredibly light DucTester for numerous testing applications. Test the leakiest to the tightest duct system. 

The complete package to start residential duct testing immediately. Includes three flow ranges (Open, 102, 74, & 47).

Package includes the newly released, industry changing DM32X gauge, roll of Grill Mask to seal registers, and a Large Carrying Case.

The 340x includes even more improvements from the former Model 340. Mount your gauge directly onto the shell for easy accessibility. A new foot design allows for a secure, sturdy base.

Retrotec's training and reporting software make testing easy.

 

This product is excluded from further promotional discounts and cannot be combined with any other offers or promo codes.

 

 

 

1 x DM32X Gauge Package

  • DM32X Gauge (Newly Released! click here for details)
  • USB-C Charging Cable
  • Cat5 Cable
  • Gauge Case
  • DM32X Magnetic Clip
  • ISO17025 calibration of DM32X
  • Gauge Calibration Verification Report

1 x 5000 Series Fan Set

  • 5000 Series Calibrated Fan (120V/60Hz, 240V/50Hz, or 110V/50Hz)
  • Range Ring A for 5000/6000 Series Fan
  • B8 Plate for 5000/6000 Series Fan
  • 8 x 4" Blank Plugs
  • Power Cord
  • 1 x Fan Cover
  • System Calibration Verification Report

1 x SmartCloth & Frame (new) - Single Fan

  • Aluminum Frame, Red Anodized
  • SmartCloth for 1000/2000/3000/5000/6000 Series Fan, Regular Height
  • Fan Crossbar Strap for Aluminum Frame
  • Case for Aluminum Frame
  • **Optional: 50" Large Aluminum Frame Offered At Additional Cost**

1 x Blower Door Tubing Kit

1 x Umbilical for 1000/5000/6000 Series Fan, 7 ft (2 m)

 

 

Model 5000 Fan

 

Flow Into:

CFM

Litres/sec

M3/h

Max Flow, per fan (60 Hz)

Reduces values by 15% for 50Hz fan

Free Air

6,400

3,020

10,874

50 Pa

5,700

2,690

9,684

75 Pa

5,400

2,549

9,175

Minimum Flow:

 

 

 

 

on Included Range B1

50 Pa

111

52

188

on Optional Range 74

50 Pa

37

17

63

on Optional Range 47

50 Pa

21

10

35

on Optional Range 29

50 Pa

9

4

15

Dimensions:

22" (55.9 cm) inlet diameter, 9.75" (24.8 cm) long, 25" (63.5 cm) height

Weight:

33.5 lb (15.2 kg) or 35.2 lb (16.0 kg) with Ring A & Plated B8 installed

Flow Accuracy:

+/-5%

Power:

120V@60hz/11A or 240V@50hz/4.9A or 110V@50Hz/ 8.9A

Recommended Fan Calibration Interval:

5 years

 

Digital Gauge Model:

DM32X

Gauge Specs:

Click Here

 

Door Panel and Frame Model:

AL250

Type of Panel:  

SmartCloth Panel & Frame – Single 1000/3000/5000/6000 Fan

Type of Frame:

Regular Sized Red Anodized Frame 

Collapsed:

27 1/8” X 53 3/8” (68.9cm X 135.6cm)

Expanded:

43 5/8” X 97 ½” (110.8cm X 247.6cm)

Frame Thickness:

1.75” (5.3 cm)

Weight:

16 lbs (7.3 kg)

 

* The max flow of the fan will vary depending on the following factors: Voltage, frequency, barometric pressure, back pressure, blade pitch, air temperature, bearing tightness, inlet air turbulence

 

* 5000/6000 series blower doors DO NOT work with the DM-2 digital gauge

 

 

What's Included:

1 x DM32X Gauge Package

  • DM32X Gauge (Newly Released! click here for details)
  • USB-C Charging Cable
  • Cat5 Cable
  • Gauge Case
  • DM32X Magnetic Clip
  • ISO17025 calibration of DM32X
  • Gauge Calibration Verification Report

1 x 300 Series Fan Set

  • 300 Series Fan
  • DC Power Supply for 300 Series Fan
  • 300 Series Fan Power Cord With Plug
  • Control Panel for 300 Series Fan
  • End Plate 300 - Range 102
  • Calibration of Fan
  • Calibration Certificate

1 x 340 DucTester Set of Range Plugs

  • 4" Plug - Range 74
  • 4" Plug - Range 47

1 x DucTester Accessory Kit

  • Large Deluxe Tool Case
  • Mylar Flex Duct for DucTester - 10" (25.4 cm) diameter x 12.5' (3.8 m) long with 13 9/16' (34.5 cm) x 13 9/16' (34.5 cm)
  • CLEAR flange
  • Grill Mask 

1 x DucTester Tubing Kit

1 x Mylar repair tape

1 x Umbilical for DucTester, 7 ft (2 m)

1 x Duct Leakage Test Report Generator Software

1 x Quick Connect Collar

Fan Model #

 

340x

 

 

Flow Into:

CFM

liters/sec

m3/h

Maximum Flow, CFM

Free Air

798

376.6

1355.8

25 Pa

719.8

339.7

1222.9

Minimum Flow

Range 102 - Standard

164.3

77.5

279.1

Range 74 - Standard

28.1

13.3

47.7

Range 47 - Standard

12.5

5.9

21.2

Range 29 - Optional

5.2

2.5

8.8

Range 18 - Optional

2.2

1.0

3.7

 

Range 11 - Optional

0.9

0.4

1.5

 

Range 07 - Optional

0.3

0.14

0.51

 

Range 03 - Optional

0.1

0.04

0.17

Dimensions

14" × 12.5" × 14.5" (35.5 x 32 x 37 cm)

Weight

14 lb (6.3 kg)

Flow Accuracy

+/-3% ISO 17025 accredited certificate available

Power Supply

Input: 120V/60Hz, 240V/50Hz, or 110V/50Hz

Output: 48V DC/ 3.31A

Power Output

0.213 hp, 159 Watts

Maximum Fan Calibration Interval

Every 5 years or sooner depending on standard

Digital Gauge Model

DM32X (Click Here)

 

* The max flow of the fan will vary depending on the following factors:
 barometric pressure, back pressure, blade pitch, air temperature, bearing tightness, inlet air turbulence, length of flex duct

 

pdf
(Size: 16.6 MB)
Banner

View All Products

Start Here




1 (855) 738-7683

Talk with a Sales Rep