  1. Quality of the Highest Standard: Here’s What That Really Means

    Building and HVAC performance testers around the world rely on calibrated fans and pressure gauges to determine the construction quality of building envelopes, duct systems, and other building components. These tools include blower doors and duct testers which have been used for decades to measure the air tightness of certain assemblies. For these tools to become and remain accurate, they must be calibrated by the manufacturer once they are built and re-calibrated after a certain period specified by the manufacture. With Retrotec tools, this is every five years for gauges and fans.

    Read more »
  2. Commercial Building Enclosure Testing

    Authored By: Sam Myers

    As building codes and owner expectations evolve, more commercial buildings across the United States are being designed to meet standards that reduce air leakage through the building enclosure. Some states are adding air tightness and testing requires to their building codes. There are also several third-party standards that require tighter building enclosures such as LEED and the Army Corps of Engineers.  The presence of a tighter building enclosure allows for lower utility bills, provides the ability to size mechanicals correctly, improves indoor air quality and reduces issues due to moisture brought in by outside air. According to the Building Envelope Technology Access Centre in Canada, most warranty callbacks for commercial new construction are due to moisture. These issues include shrinkage (nail pops and cracked concrete), water intrusion from poor grading, cracks and bad flashing details, interior finish damage from stains and joint movement,

    Read more »
  3. Duct Testing Best Practices

    Authored By: Sam Myers

    Testing ductwork in residential HVAC systems for air tightness is essential to ensure a home will be energy efficient and comfortable. Tighter ducts help homes perform better by allowing conditioned air to travel to its intended destination. They also keep newly conditioned air from escaping to the outside of the home. More states and municipal code jurisdictions are including duct sealing and testing requirements in their energy codes for residential new construction. It is also a part of the RESNET HERS Rating process as well as a function of BPI Analysts when they perform energy audits. There are two methods used for testing ducts: Total duct leakage and leakage to outside (LTO). It is best to verify with local code requirements to see which method is specified. Some state and local codes specify a target for both methods. Both methods require the use of a calibrated duct testing fan combined with a pressure and flow gauge such as the Retrotec

    Read more »
  4. Stay Safe Long after the Storm - Steps to Make Sure your House is Healthy after Hurricane Florence

    By: Sam Myers, Retrotec and Kristi Brodd, Advanced Energy

    Hurricane Florence brought record amounts of rainfall and devastating flooding across North Carolina, especially in the eastern part of the state. According to CNN measurements, some cities saw close to 3 feet of rain over four days, which is the highest rainfall total for any tropical system to hit the East Coast of the United States.

    As flooding recedes, many people are returning to their homes and beginning the restoration process. If you are moving back into a home that was flooded, it is extremely important to become knowledgeable on moisture management and take the necessary steps to keep your house safe and healthy for you and your family. Just because the water is gone and your house looks back to normal, does not mean that there is no damage or dangerous mold behind the walls, floors and ceiling.

    Many families suffered the effects of mold after flooding caused by Hurricane Floyd in 1999. Some

    Read more »
  5. DM32 Gauge will not charge. What do I do?

    Please check Retrotec USB chargers for the marking shown in the below image.
     

     

    There was an issue with some past DM32 chargers that resulted in not being able to charge the gauge from a fully depleted (0%) battery level. There will be a letter in the lower right-hand corner. If it has a “D” shown please notify [email protected].
     
    Affected chargers are from 2018 or prior. Retrotec can replace the charger during your DM32's recommended 5-year calibration service. 

    Please contact [email protected] if your gauge isn't working for any other reason, as well.

    Read more »
  6. Why does FanTestic start at the highest pressure first?

    We start at the highest pressure and work downward for two reasons. 

    1. It helps the fans reach the target pressures faster. The speed control algorithm works faster going from a higher pressure to a lower pressure.
    2. It helps you properly select your Range Ring for the test. By starting with the largest possible range (highest flow) to test at your highest pressure you ensure the minimum possible range changes while testing. Ideally, you don't want to change ranges in mid test because it wastes time. 
    Read more »
  7. Why does my Q4 (flow at 4 Pa) result have such high uncertainty?

    You need to consider that there is a fundamental issue of uncertainty with using 4 Pa as a reference pressure. Just imagine, if there is even a 1 Pa fluctuation, due to so many possible sources that can cause pressure fluctuations as you know, the pressure measurement already has an uncertainty of +/- 25% error. Consider that for almost all airtightness testing standards across the world, the reference pressure for Flow results are either 50 Pa or 75 Pa.

    Read more »
  8. Is using a positive duct test pressure advantageous?

    The main disadvantage to positive duct test pressure is that it blows off register seals or makes them leak. An LBL study showed a wide dispersion of results when the same duct test was repeated many times.  Depressurizing will allow the use of lower sticking masking materials that are less likely to pull off the paint. In some cases plastic food wrap will work.

    The main advantage to positive duct test pressure is that the flex duct doesn't contract as much. In cases where the flex runs to the ceiling this contraction effect might cause problems.

    Testing using depressurization will usually result in less leakage because gaps and seams will be pulled closed”

    Read more »
  9. Quick Tips for Testing Ducts at Rough-Ins

    Authored By: Sam Myers

    Whether it’s for a building code, third-party home performance program, HERS rating or quality control, testing ducts on new construction homes before the drywall is installed is a good idea to easily fix issues. Once the drywall is installed, it can be difficult to access certain parts of the duct system that need air sealing, especially if there are ducts in chases or between floors. Sometimes it can be tricky to set up your duct tester at rough-in since you typically don’t have a grille to tape the flange to, especially if the return is in the ceiling. Unfortunately, duct mask doesn’t stick to wood and mastic very well. Visible mastic is typically a sign of a job well done when it comes to air sealing. However, it can be frustrating if you don’t have a good system for keeping your flange and flex from falling while you are running a test or hunting down leaks with a smoke device. Setting up a duct test is already one

    Read more »
  10. Get More From Your Blower Door

    A comprehensive guide to getting the most out of your blower door system
    Authored By: Sam Myers

    A blower door system can do much more than tell you how much your building is leaking. It can also help you determine the location and severity of the leaks in different zones. There are also cases where you can use your blower door to determine if some ventilation systems are working properly. Knowing the tightness of a home and finding leaks is helpful to HERS Raters, BPI analysts, insulators and HVAC contractors. In this article we’ll introduce the blower door system and how it works for those who are new to the building performance industry. Then we’ll get into various methods to make your blower door work harder, impress your clients and increase the services you offer. 

    Air Tightness: Why Do We Care?

    The reason we care about air tightness in

    Read more »