Monthly Archives: June 2019

  1. Blower Door Testing in 1915?

    This is the 2nd installment of a monthly column from Ben Walker, Co-CEO of Retrotec. Ben's column focuses on observations on the art and science of high-performance building and home testing. 

    A blower door test, along with before and after load calculations of a leaky 1915 home, show the value of these technologies for remodelers and homeowners.

    A lot has been written about making new homes energy efficient, comfortable and healthy. That's important, but as more communities with high-performance new homes become available, more owners of existing homes want the same benefits.

    Just tightening up a home isn't enough, however. Homeowners want you to quantify the improvements. That's where testing earns its keep.

    Weatherization contractors and remodelers who specialize in energy retrofits talk about "testing

    Read more »
  2. Let's Talk Tubing: Pressurizing a Building with a Blower Door

    Author: Sam Myers, Retrotec

    When pressurizing a building with a blower door, did you know that extra tubing must be added to the Channel B side of your gauge if you are not using a Retrotec DM32? If this tubing connection is neglected, you will have a reading that is approximately 20% high due to the open Channel B port that is referencing the indoor pressure of 50Pa instead of the outdoor pressure. Therefore, the extra tube is needed to connect that port on Channel B to the outside so that it is referencing the outside instead of the pressure induced by the blower door.

    However, the Retrotec DM32 automatically

    Read more »