Double Hi-Power
With only two high-power fans and a whopping 16,200 CFM of flow, this system will be able to handle most of your testing needs – from small commercial buildings to an entire floor in a multi-family apartment building. Faster set up than 3 Standard power Fans.
Included is a larger size, easy-to-install aluminum frame door panel which adjusts to accommodate those enclosures that have larger than standard doorways. Extra crossbars help keep the frame secure in the doorway even under high test pressures.
It also includes the newly released, industry changing DM32X gauge.
Who uses it?
- Energy Auditors, HVAC Contractors, Building Contractors & Remodelers, Home Inspectors
2 x DM32X Gauge Package
- DM32X Gauge (Newly Released! click here for details)
- USB-C Charging Cable
- Cat5 Cable
- Gauge Case
- DM32X Magnetic Clip
- ISO17025 calibration of DM32X
- Gauge Calibration Verification Report
Each fan set contains:
- 6000 Series Calibrated Fan
- High Power Drive for 6000 Series Fan (120V/60Hz, 240V/50Hz, or 110V/50Hz)
- Range Ring A for 5000/6000 Series Fan
- B8 Plate for 5000/6000 Series Fan
- 8 x 4" Blank Plugs
- 2 x Fan Cover
- System Calibration Verification Report
- Large 50" Aluminum Frame
- Large #5 Crossbar
- 3 x Fan Crossbar Strap for Aluminum Frame
- Double Fan Cloth for Large 50" Aluminum Frame
- Large Roll Up Cloth Case
- 2 x Large #6 Crossbar
Model 6000 Fan |
||||
Flow Into: |
CFM |
Litres/sec |
M3/h |
|
Max Flow, per fan (60 Hz)
|
Free Air |
8,100 |
3,823 |
13,762 |
50 Pa |
7,700 |
3,634 |
13,082 |
|
75 Pa |
7,400 |
3,492 |
12,573 |
|
Minimum Flow: |
|
|||
on Included Range B1 |
50 Pa |
95 |
49 |
161 |
on Optional Range 74 |
50 Pa |
37 |
17 |
63 |
on Optional Range 47 |
50 Pa |
21 |
10 |
35 |
on Optional Range 29 |
50 Pa |
9 |
4 |
15 |
Dimensions: |
22" (55.9 cm) inlet diameter, 9.75" (24.8 cm) long, 25" (63.5 cm) height |
|||
Weight: |
33.5 lb (15.2 kg) or 35.2 lb (16.0 kg) with Ring A & Plated B8 installed |
|||
Flow Accuracy: |
+/-5% |
|||
Power: |
120V@60hz/22.0A or 240V@50hz/10.9A or 110V@50Hz/22.0A |
|||
Recommended Fan Calibration Interval: |
5 years |
Digital Gauge Model: |
DM32X |
Gauge Specs: |
Door Panel and Frame Model: |
AL265 |
Type of Panel: |
Cloth For Large Frame – Double 1000/3000/5000/6000 Fan |
Door Panel and Frame Model: |
AL261 |
Type of Panel: |
Cloth For Large Frame – Single 1000/3000/5000/6000 Fan |
Door Panel and Frame Model: |
AL260 |
Type of Panel: |
Large Frame – Single 1000/3000/5000/6000 Fan |
Type of Frame: |
Large Sized Red Anodized Frame |
Collapsed: |
31 5/8” X 59 1/2” (80.3cm X 151.1cm) |
Expanded: |
51” X 109 1/4” (129.5cm X 277.5cm) |
Frame Thickness: |
1.75” (5.3 cm) |
voltage, frequency, barometric pressure, back pressure, blade pitch, air temperature, bearing tightness, inlet air turbulence