Model 5120F with Hard Panel
Model 5120F with Hard Panel does the same job as the Model 5100F cloth panel, but also includes the modular hard panels for quick setup and an professional look.
Includes fan case, tool case plus a large aluminum frame and cloth panel for tight enclosures.
It also includes the newly released, industry changing DM32X gauge.
Why Retrotec for Enclosure Integrity?
All Retrotec systems include tech support from Retrotec who originated the idea of Enclosure Integrity testing in 1984. They promoted it within NFPA and in 1986 wrote the first Enclosure Integrity standard. Retrotec has been the lead researcher for enclosure testing ever since. Every major clean agent system manufacturer worldwide relies on Retrotec’s expertise for both hold time and peak pressure predictions.
1 x DM32X Gauge Package
- DM32X Gauge (Newly Released! click here for details)
- USB-C Charging Cable
- Cat5 Cable
- Gauge Case
- DM32X Magnetic Clip
- ISO17025 calibration of DM32X
- Gauge Calibration Verification Report
1 x 5000 Series Fan Set
- 5000 Series Calibrated Fan (120V/60Hz, 240V/50Hz, or 110V/50Hz)
- Range Ring A for 5000/6000 Series Fan
- B8 Plate for 5000/6000 Series Fan
- 8 x 4" Blank Plugs
- Power Cord
- 1 x Fan Cover
- System Calibration Verification Report
1 x Large Frame Package
- Large Aluminum Frame
- Large #5 Crossbar
- 3 x Fan Crossbar Strap for Aluminum Frame
- Single Fan Cloth for Large 50" Aluminum Frame
- Large Roll Up Cloth Case
- 2 x Large #6 Crossbar
1 x Hard Panel Set for 1000/2000/3000/5000/6000 Series Fan
4 x Roll of Grill Masks
1 x Blower Door Tubing Kit
1 x Umbilical for 1000/5000/6000 Series Fan, 7 ft (2 m)
Model 5000 Fan |
||||
|
Flow Into: |
CFM |
Litres/sec |
M3/h |
Max Flow, per fan (60 Hz) |
Free Air |
6,400 |
3,020 |
10,874 |
50 Pa |
5,700 |
2,690 |
9,684 |
|
75 Pa |
5,400 |
2,549 |
9,175 |
|
Minimum Flow: -on Range B29 |
50 Pa |
9 |
4 |
15 |
Dimensions: |
22" (55.9 cm) inlet diameter, 9.75" (24.8 cm) long, 25" (63.5 cm) height |
|||
Weight: |
33.5 lb (15.2 kg) or 35.2 lb (16.0 kg) with Ring A & Plated B8 installed |
|||
Flow Accuracy: |
+/-5% |
|||
Power: |
120V@60hz/11A or 240V@50hz/4.9A or 110V@50Hz/ 8.9A |
|||
Recommended Fan Calibration Interval: |
5 years |
Digital Gauge Model: |
DM32X |
Gauge Specs: |
Door Panel and Frame Model: |
PN201 |
Type of Panel: |
Hard Panel - Single 1000/3000/5000/6000 Fan |
* The max flow of the fan will vary depending on the following factors: Voltage, frequency, barometric pressure, back pressure, blade pitch, air temperature, bearing tightness, inlet air turbulence
* 5000/6000 series blower doors DO NOT work with the DM-2 digital gauge